
Choosing a Chemistry Analyzer for Your Workflow
Rated throughput counts tests per hour.

The Mindray BS-480 clinical chemistry analyzer is a fully automated, discrete, random-access system designed for medium- to high-volume laboratories. With a constant throughput of 400 tests per hour—upgradable to 560 tests per hour with an optional ISE module—90 sample positions, and 80 refrigerated reagent positions, it meets the clinical laboratory demand for fast and accurate routine and STAT testing. A 12-wavelength grating optical system, permanent glass cuvettes, and 8-step automatic washing make the BS-480 a reliable choice for diagnostic laboratories.
Price on request
Submit your inquiry basket to confirm pricing and availability.
The Mindray BS-480 is a fully automated, discrete, random-access clinical chemistry analyzer designed for routine, STAT, urine, and homogeneous immunoassay testing in diagnostic laboratories. It is a floor-standing system intended primarily as a primary analyzer in medium-volume laboratories and as a back-up unit in large laboratories. Key performance specifications: • Throughput: 400 photometric tests per hour constant; up to 560 tests per hour with the ISE module installed. The ISE module alone performs up to 240 tests per hour (K⁺, Na⁺, Cl⁻). • Samples: 90-position sample tray for primary or secondary tubes and sample cups; sample volume 1.5–45 µL in 0.1 µL increments. • Sample probe: liquid-level detection, clot detection, and vertical/horizontal collision protection. Automatic internal and external washing with carry-over <0.05%. • Automatic dilution: pre- and post-sample dilution up to 1:150 within the same reaction cuvette. • Integrated barcode reader: for sample and reagent programming, compatible with Codabar, ITF, Code128, Code 39, UPC/EAN, and Code 93. The optical system uses a grating design covering 340–800 nm and supports monochromatic and bichromatic measurement. Absorbance range and resolution are suitable for a broad range of clinical analytes. The reaction system features a rotating rotor with 90 permanent glass cuvettes, a 5 mm optical path length, and a reaction volume of 120–360 µL. Reaction temperature is controlled at 37 °C. Single- to quadruple-reagent chemistries (R1, R2, R3, R4) are supported. The reagent compartment has 80 positions with 24-hour uninterrupted refrigeration at 2–10 °C. Reagent volumes are adjustable from 45–350 µL for R1 and 10–350 µL for R2–R4. The reagent probe performs liquid-level detection, collision protection, and inventory checks. An 8-step cuvette washing station with concentrated detergents minimizes carry-over. The software offers a user-friendly interface, real-time analytical and carousel status monitoring, a bidirectional LIS interface, Levy-Jennings and Twin-Plot charts for quality control, and customizable reflex testing. Daily maintenance takes approximately 5 minutes, and the front-loaded reagent compartment allows easy access for service.
The Mindray BS-480 is designed for a broad range of clinical chemistry testing in diagnostic laboratories. Its primary intended use is as the main analyzer in medium-sized laboratories and as a back-up instrument in large laboratories. Other key applications include emergency department STAT testing, specialized outpatient clinics, and clinical research settings. The system supports routine chemistry, STAT testing, urine analysis, and homogeneous immunoassays. Diagnostic panels available on the BS-480 include: • Lipid Panel: Total Cholesterol, Triglycerides, HDL-C, LDL-C, and Apolipoproteins. • Inflammation and Rheumatism Panel: CRP, RF, and ASO. • Pancreatitis Panel: Amylase and Lipase. • Electrolyte Panel (with optional ISE module): Potassium, Sodium, and Chloride at up to 240 tests per hour. • Other routine analytes: Glucose, Urea, Creatinine, Uric Acid, Albumin, Total Protein, Total and Direct Bilirubin, liver enzymes (ALT, AST, ALP, GGT), and other standard biochemistry parameters. • Urine analysis for parameters such as creatinine and albumin (ACR ratio), useful in kidney disease screening. With automatic dilution up to 1:150, samples with abnormally high or low concentrations can be measured without manual dilution. STAT operation with automatic prioritization of emergency samples makes the BS-480 suitable for time-sensitive clinical departments.
Technical specifications
Specifications for this product are being finalised. Request the datasheet and we will send it directly.
Register a single service request and our team will confirm the service type, engineer and schedule.

Biotecnica · BT 1500
Biotecnica BT 1500 Clinical Chemistry Analyzer for laboratory workflows.
Price on request

Biotecnica · BT 3000 Plus
Biotecnica BT 3000 Plus clinical chemistry analyzer with up to 300 chemistry tests per hour.
Price on request

Biotecnica · BT 3500
Biotecnica BT 3500 Clinical Chemistry Analyzer for laboratory workflows. Documented throughput: 360 tests/hour without ISE.
Price on request

Hitachi · 7020
Hitachi 7020 Clinical Chemistry Analyzer for laboratory workflows. Documented throughput: 200 tests/hour.
Price on request

Hitachi · 7080
Hitachi 7080 Clinical Chemistry Analyzer for laboratory workflows. Documented throughput: 360 tests/hour.
Price on request

Hitachi · 7180
Hitachi 7180 Clinical Chemistry Analyzer for laboratory workflows. Documented throughput: 800 tests/hour.
Price on request