How to Choose a Hematology Analyzer

Record both the daily sample count and the busiest hour.

How to Choose a Hematology Analyzer

Start a hematology analyzer purchase with a week of your laboratory's work. Once you know when specimens arrive, which report you need and who reviews flagged results, it becomes easier to compare instruments. Speed and price matter when they are tied to the work you are trying to get done. This guide walks through the busiest hour, the report, the supplies budget, a fair demonstration and the decisions you will need to make at handover. [3]

Look at when samples arrive over a week

Write down the number of complete blood count, or CBC, specimens by hour. Include courier arrivals, urgent requests and shift start and end times. If you use figures from your laboratory information system, check whether they show the time an order was entered or the time the specimen actually reached the bench. The latter is usually more useful when estimating the load on the instrument. Compare an ordinary quiet day and a busy day to see how widely those loads vary.

Suppose a laboratory receives 160 specimens in a day, with 80 arriving in a single hour. Another lab might receive the same 160 specimens in smaller groups spread across the day. The first lab could have registration, preparation, loading, counting, flag review and report authorization competing for attention at once. When a supplier quotes a speed, ask where the measurement starts and ends. The analyzer's counting rate is only one part of the time it takes to deliver a report.

Put a real report beside your worklist

Ask each supplier to show one routine example and one test report with a flag. Look at the white-cell, red-cell and platelet information, how percentages and counts appear, and how the white-cell groups are named. A three-part differential reports three groups of white cells. A five-part differential usually gives separate entries for five main groups. Sysmex's XP series provides an example of three-part reporting, and its XS series documents five-part differentiation. Look at the documentation for the actual model and version before deciding what will be available. [1, 2]

Ask the technical lead what output is needed every day and which requests currently require more review or referral. Read a flag on the analyzer during the demonstration and see what information is written to the test record. If the lab already has reporting software, open the same test result there. Some details may be visible only on the instrument. Staff should know which display to open when they need the original message or another part of the report.

Compare tubes, sample volumes and loading

List the tubes and containers the lab uses regularly. Ask the supplier to identify what the quoted instrument supports. Check how the operator presents an individual sample or loads a group, and what accessories are involved. If low-volume samples are part of the workload, ask which sample mode and equipment the supplier proposes for them. Request documentation for the unit and the supplied configuration. A feature mentioned in a product family brochure can belong to a different model or option. [1, 2]

Add operator time to the comparison. Two analyzers with similar counting speeds may take a different number of steps to read a barcode, move a tube or accept urgent work. Have a staff member who will use the equipment run through those steps. Include one approved test case in which a label does not read or an order is incomplete. Watch where the user sees the problem and how the record stays visible until someone fixes it.

Tie the supplies budget to the reports you release

The price of a reagent pack tells you what it costs to buy a material the analyzer uses. The laboratory also needs to know which controls, cleaning materials and other consumables belong in the budget. Ask about the nominal test count, the allowed time after opening and the typical delivery schedule for each pack. Some of the material may go to preparation, quality control or repeats. Divide the costs you want to compare by the number of reports the laboratory can actually release. [3]

Here is an illustrative example. A lab spends 12 million tomans per month on a group of supplies. At 600 reports, those supplies add 20,000 tomans per report. In a slower month with the same spend and 400 reports, the cost rises to 30,000 tomans per report. These are assumed figures for a subset of costs. Replace them with recent quotes, actual package sizes and your report volumes. If one item takes a long time to arrive, include the likely effect of a shortage on downtime and referrals in the discussion.

Give suppliers the same demonstration

Ask the suppliers to show the same short list of approved test scenarios. You could include several routine requests, an urgent request added midway through the work and one example with a flag the laboratory needs to review. Agree on the test setup with the technical lead and use authorized test data. Record the time of registration, the first available result and the authorized report as separate points. Note every stage where a member of staff has to take an additional action.

Record what the operator does as well as the elapsed time. Can the operator retrieve a previous report or the exact flag after moving on to another sample? If a specimen arrives without a matching order, where will the operator see that and record it for follow-up? Can the next shift identify which results are still awaiting review? A short demonstration can miss real problems, but giving suppliers the same workload makes it easier to spot differences that brochure figures alone leave out.

Agree on service, installation and downtime before signing

Get the serial number, software version, included accessories, installation, training, warranty scope and service response terms in writing. Find out who answers first when the device is unavailable, who can arrange a site visit and who supplies covered parts. If the lab has a single device, plan how to manage a one-day interruption. Identify who handles urgent requests, where specimens would go and how someone will notify the requesting team of a delay. Bring the answers into the price discussion. [3]

At handover, keep the vendor's startup demonstration alongside the evidence your laboratory requires for routine reporting. Agree ahead of time who will review the delivery notes, who will check the performance evidence and which unresolved items will hold work. An analyzer can power on and produce a demonstration report while data transfer or an option in the contract remains incomplete. Record the issue with its owner and expected date so people can follow up once the supplier leaves.

Use the checklist before buying and again after a month

  • How many tubes reach the bench in the busiest hour, and how many reports are due at that time?
  • What does a routine report and a flagged result look like on the device and in the reporting software?
  • Which tube types, presentation modes and accessories come with this exact offer?
  • How much does each pack cost, how long can it be used once open, and how will supplies reach the laboratory during the first three months?
  • Who trains staff, accepts the installation and answers service calls?
  • What will we review after the first month, and who will keep the record?

For the first-month review, pick a quiet day and a peak period from actual work. Compare time to the first urgent report, items held for review, shortages and service calls with the assumptions from the purchase. If you find a difference, review it with the person who did the work. A training session, a better place for items on the bench, or a clearer handoff can solve some problems. For an issue linked to the supplier's commitments, use the written terms and the original handover record to organize the follow-up.

References

  1. Sysmex — XP-series hematology analyzer specifications